Passive:Verification

Aus Wufiwiki
Zur Navigation springenZur Suche springen

Results of Passive House Verification

This page shows the different subpoints of the output of the Passive House Verification. There will be a short description of the output parameters for each subpoint as well as a screenshot.

Building Information

Building information

The first section summarizes general information about the building itself and important boundary conditions such as the interior temperature or the internal loads.

Passivehouse requirements

Passivehouse requirements

The primary passive house requirements depend mostly on energy demand, mainly in form of cooling and heating as well as primary energy demand. All values are given in a specific value (per square meter/feet) and in total. Heating and cooling demand also provide a peak value(month), which is estimated by the extreme weather conditions in the climate tab.

Secondary Passivehouse Requirements

Secondary requirements

The secondary requirements consist of the HRV efficiency and a percentage chance of overheating of the building. Depending on the values WUFI®Passive will give recommendation if a seperate cooling system is needed or not.

Building Elements

Building elements

The building elements describes the influences of windows, HVAC systems and electric devices on the energy demand.

Windows

The graphic shows the heat losses and gains of solar radiation through windows depending on the orientation. Also average values for all windows are given together with the total glazing area.

HVAC

The energy demand of all HVAC devices is summerized here.

Electricity

The energy demand of all other electric devices is listed here.

Heat Flow

Heat flow

Heat gains and losses are divided on different causes.
Heat gains are seperated into solar gains, inner sources, thermal bridges and mechanical heating.

Heat losses are seperated into windows&doors, the building envelope and natural and mechanical ventilation.

Both statistics are displayed in a pie chart.

Climate

Climate

Gives a summary of the information given in the localization/elimate section of the tree and also calulations of not given values (e.g. ground temperature) and puts it together into a graph.
The second graph displays the solar radiation and its orientation.

Calculation Parameters

Calculation parameters

Someone else might explain this better than i do.

Annual Heat/Cooling Demand

Heat/Cooling demand

Opposes annual heat gains and losses and thereby calculates the annual heat/cooling demand.

Heating/Cooling Load

Heat/Cooling load

Someone else might explain this better than i do.

Areas

Areas


Thermal Brigdes

Thermal bridges

Summarizes all thermal bridges given in the thermal bridge tab of the tree and its heat gains and losses.

Windows

Windows

Shows the number, orientation and specific values of all windows and their influence on the heat gains and losses. These results are used in the calculation of the heating and cooling demand.

Summary Building Envelope

Building envelope

Dimensions of all building elements as well as their U- or Psi-Value. Also the transmission losses of each element, which are also needed for the heat gain/loss statistic are given.

The respective shading effect of each orientation is given here too.

HVAC Systems

HVAC

An enumeration of all HVAC systems and their influence on the DHW consumption, heat gains/losses and primary energy demand or a equivalenct CO2 emission.

Ventilation

Ventilation

Someone else might explain this better than i do.

Electricity Demand - Auxiliary Electricity

Auxiliary electricity

A table containing the energy demand of all HVAC and all affiliated systems.

Electricity Demand Of Electric Devices

A list of all input electric devices and their annual electric demand.
As input of residential and non-residential building differs, WUFI has different graphics for each type.

Residential
Non-residential


Internal Heat Gains

Heat gains


DHW and Distribution

DHW