Passive:Dynamic Simulation: Unterschied zwischen den Versionen

Aus Wufiwiki
Zur Navigation springenZur Suche springen
Keine Bearbeitungszusammenfassung
Zeile 1: Zeile 1:
== Switch to dynamic Mode ==
== Switch to dynamic Mode ==
The Status and Result Box displays the status of the input e.g. if data is missing or unrealistic and if all information is given, a small portion of the results.
 
<br>
It can be minimized by clicking the grey X-button. This can be useful e.g. when reading the [[Passive:Results|Results]]. The button then changes to a green arrow and by clicking whom, the box can be reestablished.
=== Set Boundary Conditions from Passive House ===
=== Set Boundary Conditions from Passive House ===


[[Bild:Passive-resultbox_error.png|left]]
[[Bild:Passive-resultbox_error.png|left]]
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results.
Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results.
<br>
<br>
Setpoints for WUFI®Plus in detail:
<br> Temperature: Design Minimal Temperature = indoor temperature, Design Maximal Temperature = overheating temperature,
<br> Ground temperature: New optional ground climate added with Relative Humidity = 99 constant, Temperature = sin curve with min/max values and phase shift from WUFI®Passive calculation
<br> Ground temperature:
<br style="clear:both" />
<br style="clear:both" />

Version vom 17. Juli 2013, 11:50 Uhr

Switch to dynamic Mode

Set Boundary Conditions from Passive House

Passive-resultbox error.png

Certain input parameters can be taken over from WUFI®Passive to WUFI®Plus. To simplify this step new a button "Set Boundary Conditions from Passive House" has been introduced. This option will set reasonable values for the dynamic simulation mode for better comparison of the results.

Setpoints for WUFI®Plus in detail:
Temperature: Design Minimal Temperature = indoor temperature, Design Maximal Temperature = overheating temperature,
Ground temperature: New optional ground climate added with Relative Humidity = 99 constant, Temperature = sin curve with min/max values and phase shift from WUFI®Passive calculation
Ground temperature: