Passive2:Inner Loads: Unterschied zwischen den Versionen

Aus Wufiwiki
Zur Navigation springenZur Suche springen
Zeile 23: Zeile 23:
=== Office equipment ===
=== Office equipment ===
[[Bild:Passive-innerloads_nonres_offequipment.png|thumb|right|Office equipment]]
[[Bild:Passive-innerloads_nonres_offequipment.png|thumb|right|Office equipment]]
Any office equipment can be enumerated here. WUFI itself knows the following devices: PC, monitor, copier, printer, server and the telephone system. If you have different ones, you can use the user defined scope. It can not be attached to a utilization pattern, therefor the utilization pattern per year can be given here.<br>
Any office equipment can be enumerated here. WUFI itself knows the following devices: PC, monitor, copier, printer, server and the telephone system. If different ones are needed, they can be inserted in the "user defined" scope. "User defined" devices can not be attached to a utilization pattern, therefor the utilization hours/year have to be given.<br>
The printer and copier also have an additional data section. The hours of utilization in energy saveing mode in hours/year can be defined, but it is optional.
The printer and copier also have an additional data section. The hours of utilization in energy saveing mode in hours/year can be defined, but are optional.
<br style="clear:both" />
<br style="clear:both" />
=== Kitchen equipment ===
=== Kitchen equipment ===
[[Bild:Passive-innerloads_nonres_kitchequipment.png|thumb|right|Kitchen equipment]]
[[Bild:Passive-innerloads_nonres_kitchequipment.png|thumb|right|Kitchen equipment]]

Version vom 23. Juli 2013, 13:27 Uhr

Depending on which building type is chosen, this section offers different input options. If a residential building is simulated in WUFI, only common household appliances and lighting have to be defined.
For non-residential buildings, kitchen and office appliances as well as the occupancy has to be defined and attached to a utilization pattern.

Residential building

Inner Loads


In this section electric devices and humidity sources are defined. They are important to estimate the energy and water demand, as well as the humidity load inside the building. In the device scope, WUFI offers a lot of common household devices, like dishwater etc. as well as the option to implement a different device.

Device scope


For each device, the quantity and the energy demand are needed and depending on the devices itself, additional data is needed: E.g. the dishwasher can be connected with the DHW or cold water.
In case the inner sources of the building are not known yet, WUFI contains a standart amount of devices in a common household which can be used by clicking on "standart dataset.

Non-residential building

Utilization pattern

Utilization pattern

The mandatory data for utilization patterns is given over the columns of the table. The additional data is useful, depending on where the pattern is attached.

Occupancy

Occupancy

Here it is defined how many occupants the building has as well as additional humidity sources. When it comes to the activity of the occupants, WUFI can differ between children, sitting adults and standing adults. It is also possible to define the pattern for these people as well the quantity of people following this pattern.
The additional data section contains a value about additional heat losses through evaporation and toilet usage/settings.
If the simulated building is a school, WUFI has default values for it.

Office equipment

Office equipment

Any office equipment can be enumerated here. WUFI itself knows the following devices: PC, monitor, copier, printer, server and the telephone system. If different ones are needed, they can be inserted in the "user defined" scope. "User defined" devices can not be attached to a utilization pattern, therefor the utilization hours/year have to be given.
The printer and copier also have an additional data section. The hours of utilization in energy saveing mode in hours/year can be defined, but are optional.

Kitchen equipment

Kitchen equipment

If the building has a kitchen, its appliances can be defined in this section. WUFI provides cooktop, dishwasher and refrigerator. In case you have different appliances, use the user defined scope.

Lighting

Lighting

Depending on the entering sunlight the required lighting is estimated. Therefore data of room geometry, glass transparancy and occupancy (utilization pattern) is needed.