==What do I need?==
==What do I need?==


This is an overview of the steps that have to be taken before you can start a calculation. On the left side of the screen you see the navigation tree with all important points which has to be defined before:
This is a short overview of the steps that have to be taken before you can start a calculation. You can see the navigation tree with all important points which has to be defined before:


[[image:WUFI-PlusNavigationTree.jpg|thumb|Navigation Tree]]
[[image:WUFI-PlusNavigationTree1.jpg|left|Navigation Tree]]


The easiest way is to start on the top of the navigation tree an edit point after point top down.
The easiest way is to start on the top of the navigation tree and edit point to point top down.
First you may enter some optional information about the [[Plus:Dialog Project|project]] and the [[Plus:Dialog Case|case]].


After the basic information you have to select the location of the project in the [[Plus:Dialog Climate|climate]] dialog for the specific climate data. Here it is also possible to edit a [[Plus:Dialog Climate|optional climate]].
First you may enter some optional information about the [[Plus:Dialog Project|project]].


When the climate is chosen, the building has to be defined. Either with the [[Plus:Dialog BuildingWizard|building wizard]] or via script file.
After some basic information you have to select a climate for the calculation. Either the measured [[Plus:Dialog Climate|climate data]] for a location or synthetic ones are possible.
 
When the climate is chosen, the building geometry has to be shaped. Either with the [[Plus:DialogBuildingWizard#Automatic building wizard|building wizard]] or by [[Plus:DialogBuildingWizard#script|vertices]].


You have to define the [[Plus:Dialog DatabaseAssemblies|assembly]] of the components. Predefined assemblies can be read from the [[Plus:Dialog DatabaseAssemblies|assembly database]]. New constructions can be edited in this dialog and you can select in the [[Plus:Dialog DatabaseMaterials|material data]] for the individual layers.
You have to define the [[Plus:Dialog DatabaseAssemblies|assembly]] of the components. Predefined assemblies can be read from the [[Plus:Dialog DatabaseAssemblies|assembly database]]. New constructions can be edited in this dialog and you can select in the [[Plus:Dialog DatabaseMaterials|material data]] for the individual layers.


In the inner climate dialog you may design the inner climate, define the loads of occupancy and additional and enter the equipment data about heating, cooling and ventilation.
The prospective [[Plus:……………… | loads]] loads can be defined in dayprofiles.
 
In [[Plus:TreeInnerClimate | Design Conditions]] temperature, moisture and ventilation conditions can be edited.


In the other parameters are the initial conditions and the accuracy of calculation to define.
In the other parameters are the initial conditions and the accuracy of calculation to define.


At last the [[Plus:Dialog AttachedZones|attached zones]] have to be specified.
At last the [[Plus:Dialog ………………|HVAC-Systmes]] have to be specified.

Aktuelle Version vom 21. Juni 2010, 09:27 Uhr

What do I need?

This is a short overview of the steps that have to be taken before you can start a calculation. You can see the navigation tree with all important points which has to be defined before:

Navigation Tree

The easiest way is to start on the top of the navigation tree and edit point to point top down.

First you may enter some optional information about the project.

After some basic information you have to select a climate for the calculation. Either the measured climate data for a location or synthetic ones are possible.

When the climate is chosen, the building geometry has to be shaped. Either with the building wizard or by vertices.

You have to define the assembly of the components. Predefined assemblies can be read from the assembly database. New constructions can be edited in this dialog and you can select in the material data for the individual layers.

The prospective loads loads can be defined in dayprofiles.

In Design Conditions temperature, moisture and ventilation conditions can be edited.

In the other parameters are the initial conditions and the accuracy of calculation to define.

At last the HVAC-Systmes have to be specified.