Passive:Wufi Passive: Unterschied zwischen den Versionen

Aus Wufiwiki
Zur Navigation springenZur Suche springen
Keine Bearbeitungszusammenfassung
Keine Bearbeitungszusammenfassung
 
Zeile 1: Zeile 1:
WUFI®Passive was developed by the Fraunhofer-Institute of Building Physics (IBP) and the Passive House Institute US (PHIUS) by combining the WUFI®Plus building simulation tool with a Passive House Verification feature to meet the needs of Passive House communities worldwide.
WUFI®Passive was developed by the Fraunhofer-Institute of Building Physics (IBP) and the Passive House Institute US (PHIUS) by combining the WUFI®Plus building simulation tool with a Passive House Verification feature to meet the needs of passive building communities worldwide.
<br>
<br>
<br>
<br>
In times of decreasing fossil fuel resources, Passive Houses have shown to be an important step towards more efficiency and less energy consumption in the building sector. By using dynamic models and hourly data, WUFI®Passive has an edge against other verification tools, and the integrated WUFI®Plus tool also has the ability of hygrothermal analysis and calculations.<br>
In times of decreasing fossil fuel resources, the implementation of passive building principles have shown to be an important step towards higher efficiency and less energy consumption in the building sector. By using dynamic models and hourly data, WUFI®Passive has an edge against other verification tools, and the integrated WUFI®Plus tool also has the ability of hygrothermal analysis and calculations.<br>
The Passive House Verification in WUFI®Passive calculates the energy demand of buildings on monthly or annual basis. Thereby transmission, ventilation, radiation and inner loads are considered. The energy gains and losses are balanced and a detailed input (heating, ventilation, HVAC etc) allows the calculation of the total energy demand. Depending on the energy sources used, the primary energy consumption is determined as well.<br>
The Passive House Verification in WUFI®Passive calculates the energy demand of buildings on monthly or annual basis. Thereby transmission, ventilation, radiation and inner loads are considered. The energy gains and losses are balanced and a detailed input (heating, ventilation, HVAC etc) allows the calculation of the total energy demand. Depending on the energy sources used, the primary energy consumption is determined as well.<br>
<br>
<br>
'''NOTE:'''<br>
'''NOTE:'''<br>
Some links on the WUFI®Passive pages lead to WUFI®Plus pages, as there are no changes in the respective pages.
Some links on the WUFI®Passive pages lead to WUFI®Plus pages, as there are no changes in the respective pages.

Aktuelle Version vom 4. Juni 2014, 12:10 Uhr

WUFI®Passive was developed by the Fraunhofer-Institute of Building Physics (IBP) and the Passive House Institute US (PHIUS) by combining the WUFI®Plus building simulation tool with a Passive House Verification feature to meet the needs of passive building communities worldwide.

In times of decreasing fossil fuel resources, the implementation of passive building principles have shown to be an important step towards higher efficiency and less energy consumption in the building sector. By using dynamic models and hourly data, WUFI®Passive has an edge against other verification tools, and the integrated WUFI®Plus tool also has the ability of hygrothermal analysis and calculations.
The Passive House Verification in WUFI®Passive calculates the energy demand of buildings on monthly or annual basis. Thereby transmission, ventilation, radiation and inner loads are considered. The energy gains and losses are balanced and a detailed input (heating, ventilation, HVAC etc) allows the calculation of the total energy demand. Depending on the energy sources used, the primary energy consumption is determined as well.

NOTE:
Some links on the WUFI®Passive pages lead to WUFI®Plus pages, as there are no changes in the respective pages.